Aspiradores Industriales ATEX Centrales Multi-étapicos

- Versiones prueba de Explosiones o versiones estandar disponibles.
- Disponibles con sacudidor de filtro manual (MFS) o con limpieza de filtro automatico (AFS) (APS)
- Disponibles tambien en Acero Inoxidable
- Tiger-Vac propone una variedad de aspiradores practicos y abordables, al igual que sistemas completos de aspiracion,con una vasta gama de aplicaciones para la industria. Nosotros podemos ayudarle a concebir un aspirador central, que responda à sus éxigencias,encontrando en ellos las mas estrictas normas de seguridad y estandares de alta calidad.
Unidad de récupéracion central , antidéflagrante à prueba polvos inflamables
- For 2.2 kW to 5 kW motor performance
- Stainless steel AISI 304 construction
- AISI 316 Electropolished available
- Compable with CD-5 EX Series
- Manual (MRP) or Automatic (ARP) reverse purge filter cleaning system with 1 cartridge & skirt cartridge filter surface: 37 200 cm² (40 ft²)
- skirt filter surface: 3 330 cm² (3.58 ft²)
- total filter surface: 40 530 cm² (43.58 ft²)
- Also available with Manual Filter Shaker (MFS) System
- *Cleanroom compatible. Can be used in the pharmaceutical industry
- Available non-explosion proof
- Recovery Capacity 10 gallons (40 litres)
ULPA - Ultra Low Penetration Air Filter
A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.
North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron. Tested as per IES-RP-CC001.3.
Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.
MRP - Manual Reverse Purge System
The Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge. By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts. This Purging System reduces maintenance down time.
The Manual Reverse Purge (MRP) works by :
1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.
2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.
Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).
Reverse Purge System will cause dust to fall off of the filter.
| Name | Description | Download |
| FRS-10/40L EX Brochure (Metric) | Technical data for FRS-10/40L EX in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| FRS-10/40L EX Brochure (Imperial) | Technical data for FRS-10/40L EX in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
- For 2.2 kW to 5 kW motor performance
- Stainless steel AISI 304 construction
- AISI 316 Electropolished available
- Compable with CD-5 EX Series
- Manual (MRP) or Automatic (ARP) reverse purge filter cleaning system with 1 cartridge & skirt cartridge filter surface: 37 200 cm² (40 ft²)
- skirt filter surface: 3 330 cm² (3.58 ft²)
- total filter surface: 40 530 cm² (43.58 ft²)
- Also available with Manual Filter Shaker (MFS) System
- *Cleanroom compatible. Can be used in the pharmaceutical industry
- Available non-explosion proof
- Recovery Capacity 15 gallons (63 litres)
ULPA - Ultra Low Penetration Air Filter
A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.
North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron. Tested as per IES-RP-CC001.3.
Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.
MRP - Manual Reverse Purge System
The Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge. By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts. This Purging System reduces maintenance down time.
The Manual Reverse Purge (MRP) works by :
1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.
2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.
Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).
Reverse Purge System will cause dust to fall off of the filter.
| Name | Description | Download |
| FRS-15/63L EX Brochure (Metric) | Technical data for FRS-15/63L EX in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| FRS-15/63L EX Brochure (Imperial) | Technical data for FRS-15/63L EX in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
- For 7.5 kW motor performance
- Stainless steel AISI 304 construction
- AISI 316 Electropolished available
- Compable with CD-7 EX Series
- Extended Series
- Manual (MRP) or Automatic (ARP) reverse purge filter cleaning system with 1 cartridge & skirt cartridge filter surface: 55 700 cm² (60 ft²)
- skirt filter surface: 5 110 cm² (5.5 ft²)
- total filter surface: 60 810 cm² (65.5 ft²)
- Also available with Manual Filter Shaker (MFS) System
- *Cleanroom compatible. Can be used in the pharmaceutical industry
- Available non-explosion proof
- Recovery Capacity 15 gallons (63 litres)
ULPA - Ultra Low Penetration Air Filter
A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.
North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron. Tested as per IES-RP-CC001.3.
Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.
MRP - Manual Reverse Purge System
The Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge. By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts. This Purging System reduces maintenance down time.
The Manual Reverse Purge (MRP) works by :
1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.
2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.
Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).
Reverse Purge System will cause dust to fall off of the filter.
| Name | Description | Download |
| FRS-63L EX EXTENDED Brochure (Metric) | Technical data for FRS-63L EX EXTENDED in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| FRS-63L EX EXTENDED Brochure (Imperial) | Technical data for FRS-63L EX EXTENDED in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
- For 7.5 kW to 15 kW motor performance
- Stainless steel AISI 304 construction
- AISI 316 Electropolished available
- Compable with CD-10 EX Series
- Automatic Purge (APS) filter cleaning system with 4 cartridges & 4 skirts Total cartridge filter surface: 111 483 cm² (120 ft²)
- Total skirt filter surface: 20 840 cm² (22.44 ft²)
- total filter surface: 132 323 cm² (142.44 ft²)
- Also available with Automatic Filter Shaker (AFS) System or Automatic Reverse Pulse (RPS) System
- *Cleanroom compatible. Can be used in the pharmaceutical industry
- Available non-explosion proof
- Recovery Capacity 40 gallons (160 litres)
ULPA - Ultra Low Penetration Air Filter
A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.
North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron. Tested as per IES-RP-CC001.3.
Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.
RPS - Reverse Pulse System

- Automatic filter cleaning system that helps remove caked-on dust from the filter.
- Pulsed air is blown from the inside towards the outside of the filter at a regular frequence.
- User can adjust the interval between the two cleaning cycles.
- Pneumatically (air) operated.
| Name | Description | Download |
| FRS-40/160L EX Brochure (Metric) | Technical data for FRS-40/160L EX in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| FRS-40/160L EX Brochure (Imperial) | Technical data for FRS-40/160L EX in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |

IP6X - T135oC
LCIE 03 ATEX 6295
- Legally certified explosion proof/dust ignition proof vacuum cleaner.
- Less than 10 Ohms of resistivity
- ULPA Filter - Included with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822. Or HEPA Filter - Optional with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- *Cleanroom compatible. Can be used in the pharmaceutical industry
- Continuous duty 3-phase explosion proof motor
- Power Unit can be attached to a Filtration System (FRS)
- Can be used as a mobile or central unit
- All stainless steel construction
- Equipped with 4 wheels for easy manoeuverability. Can also be equipped with slots for fork lift capability
ULPA - Ultra Low Penetration Air Filter
A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.
North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron. Tested as per IES-RP-CC001.3.
Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.
| Name | Description | Download |
| CDPU-5/7/10 EX Brochure (Metric) | Technical data for CDPU-5/7/10 EX in metric units (Millimeters, Kilograms...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| CDPU-5/7/10 EX Brochure (Imperial) | Technical data for CDPU-5/7/10 EX in imperial units (Inches, Pounds...) | Brochure Letter (8½" × 11") Brochure A4 (210mm × 297mm) |
| ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas | Certification Document | descargar |
Notas:
- Los filtros HEPA - tienen una eficacia de 99,995% sobre los 0,3 microns - Probado IEST RP-CC001.3 - H14 SIPM segun el metodo EN 1822.
- Filtros ULPA -tienen una eficacia de 99,999% sobre los 0,3 microns - tienen eficacia de filtracion de 99,9995% à 0,18 microns - Probado IEST RP-CC001.3 - U15 SIPM segun el metodo EN 1822
- Todos los filtros HEPA / ULPA de Tiger-Vac son probados DOP cuando son instalados, ya sea à favos del aire o en contra del aire, dentro del aspirador.
- Todos los filtros hepa HEPA / ULPA de Tiger-Vac son ensamblados unicamente con 3 pernos incluidos.un empaque espécialemente hecho con le fin de prevenir las fugas durante la duracion del filtro para asegurar la salud y seguridad del utilizador final.