CD/EUR-36L EX DT (MRP) ULPA WITH SS CART
For the Food/Pharma Processing Industries - Manual Reverse Purge
Certifications
|
CD-EX Models Certified for:
CLEANING MACHINES For Hazardous Locations (Classes C1618 01 & C1618 81)
Division 1, Class I, Group D and Class II, Groups F and G, T3C
Division 1, Class II Group E (metal dust) motor and switch available
Division 2, Class I Group D and Class II, Groups F and G, T3C
|
|
|
CD EX Series IECEx 3rd Party Certified
Ex d IIB T4 Gb
Ex t IIIC T135°C Db IP65
IECEx LCI 10.0040 X
Certified for providing an Equipment Protection Level of EPL Db and EPL Gb
|
|
|
GUARANTEED for the Safe Recovery of Combustible/Conductive Dusts
|
|
|
ESD Safe Vacuum Systems for Hazardous Locations are designed to prevent ignition hazards.
We use metal parts or Static Dissipative Powder Coating to prevent Electrostatic Discharge (ESD)
|
|
|
Complies with NFPA 77 "Recommended Practice on Static Electricity"
|
|
|
|
Features
- Legally certified explosion proof/dust ignition proof
- Less than 10 ohms of resistivity
- Continuous duty single phase or 3-phase (TEFC) explosion proof/dust ignition proof motor
- ULPA filter with an efficiency of 99.999% at 0.12 micron. Filtration efficiency of 99.9995% at 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822. All of our ULPA vacuum systems are aerosol leak tested before leaving our facility - included
- Muffler assembly, made of stainless steel with sound insulating foam to ensure quiet operation, is included
- Cleanroom compatible with ISO Class 4 (former Class 10). Can be used in the Pharmaceutical industry
- Manual Reverse Purge (MRP) with static dissipative reverse purge cartridge
- Static conductive aluminized spun bond reverse purge cartridge is contained within a removable filter chamber
- All stainless steel Type 304 construction
- Detachable recovery tank (DT) for easy disposal of recovered materials
- Static dissipative poly liner and clip for the easy and safe disposal of recovered materials - available
- Vertical mounting for areas with space constraints
- Equipped with a Carriage with Suspended Motor Top (CSMT) and tool basket. Includes static dissipative wheels
- Optional Ø1.5" (Ø38 mm) or Ø2" (Ø50 mm) tools & accessories
- Motor and switch for use in the presence of conductive metal dust is available.
North-America: Class II, Group E
Europe: Dust Group IIIC
- Other motor performances available
|
Technical Specs - North America
Specifications | 112157A1-SS | 112157A2-SS | 112157A5-SS | 112158A3-SS | 112159A3-SS | 112160A1-SS |
Model Name | CD/EUR-36L EX DT (MRP) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS F & G | CD/EUR-36L EX DT (MRP) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS F & G | CD/EUR-36L EX DT (MRP) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS F & G | CD/EUR-36L EX DT (MRP) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS F & G | CD/EUR-36L EX DT (MRP) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS E, F & G | CD/EUR-36L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS E, F & G |
Type | Electric | Electric | Electric | Electric | Electric | Electric |
TEFC Motor | Yes | Yes | Yes | Yes | Yes | Yes |
Tension | 460 V | 230 V | 575 V | 120 V | 120 V | 460 V |
Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
Phase | Three | Three | Three | Single | Single | Three |
Wattage | 1480 W | 1480 W | 1480 W | 1110 W | 1110 W | 1480 W |
Power | 2 HP | 2 HP | 2 HP | 1.5 HP | 1.5 HP | 2 HP |
Amperage | 2.6 A | 5.2 A | 2.1 A | 15 A | 15 A | 2.6 A |
Air Flow | 158 CFM | 158 CFM | 158 CFM | 125 CFM | 125 CFM | 158 CFM |
Vacuum Pressure | 130 " H20 | 130 " H20 | 130 " H20 | 120 " H20 | 120 " H20 | 130 " H20 |
VRV Setting | 80 " H20 | 80 " H20 | 80 " H20 | 80 " H20 | 80 " H20 | 80 " H20 |
Type of Power Outlet | Not Included | Not Included | Not Included | Not Included | Not Included | Not Included |
Suction Inlet Port | 2 " | 2 " | 2 " | 2 " | 2 " | 2 " |
Cart Type | Detachable Tank (DT) | Detachable Tank (DT) | Detachable Tank (DT) | Detachable Tank (DT) | Detachable Tank (DT) | Detachable Tank (DT) |
Filter Cleaning | Manual Reverse Purge (MRP) | Manual Reverse Purge (MRP) | Manual Reverse Purge (MRP) | Manual Reverse Purge (MRP) | Manual Reverse Purge (MRP) | Manual Reverse Purge (MRP) |
Dust Recovery Tank | 9.5 Gal | 9.5 Gal | 9.5 Gal | 9.5 Gal | 9.5 Gal | 9.5 Gal |
Length | 30.5 " | 30.5 " | 30.5 " | 30.5 " | 30.5 " | 30.5 " |
Width | 22 " | 22 " | 22 " | 22 " | 22 " | 22 " |
Height | 70 " | 70 " | 70 " | 70 " | 70 " | 70 " |
Weight (Vacuum Only) | 218 lb. | 218 lb. | 218 lb. | 218 lb. | 218 lb. | 218 lb. |
Cord Length | 50 ft. | 50 ft. | 50 ft. | 50 ft. | 50 ft. | 50 ft. |
Specifications | 112160A2-SS | 112160A5-SS |
Model Name | CD/EUR-36L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS E, F & G | CD/EUR-36L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS E, F & G |
Type | Electric | Electric |
TEFC Motor | Yes | Yes |
Tension | 230 V | 575 V |
Frequency | 60 Hz | 60 Hz |
Phase | Three | Three |
Wattage | 1480 W | 1480 W |
Power | 2 HP | 2 HP |
Amperage | 5.2 A | 2.1 A |
Air Flow | 158 CFM | 158 CFM |
Vacuum Pressure | 130 " H20 | 130 " H20 |
VRV Setting | 80 " H20 | 80 " H20 |
Type of Power Outlet | Not Included | Not Included |
Suction Inlet Port | 2 " | 2 " |
Cart Type | Detachable Tank (DT) | Detachable Tank (DT) |
Filter Cleaning | Manual Reverse Purge (MRP) | Manual Reverse Purge (MRP) |
Dust Recovery Tank | 9.5 Gal | 9.5 Gal |
Length | 30.5 " | 30.5 " |
Width | 22 " | 22 " |
Height | 70 " | 70 " |
Weight (Vacuum Only) | 218 lb. | 218 lb. |
Cord Length | 50 ft. | 50 ft. |
|
Please note that specifications are subject to change without notice