Ask a Question
CR-1000 (CV) SERIES
Pharma - Dry Recovery Only with Safe Containment Canister for Potent Carcinogenic Powders
/tempFiles/Guest-246.JPG?applID=4&itID=170&scID=22
/tempFiles/Guest-266.JPG?applID=4&itID=170&scID=22 /tempFiles/Guest-267.JPG?applID=4&itID=170&scID=22 /tempFiles/Guest-363.JPG?applID=4&itID=170&scID=22 /tempFiles/Guest-852.JPG?applID=4&itID=170&scID=22 /tempFiles/Guest-263.JPG?applID=4&itID=170&scID=22 /tempFiles/Guest-264.JPG?applID=4&itID=170&scID=22 /tempFiles/Guest-265.JPG?applID=4&itID=170&scID=22

Downloads


Description Link
CR-1000 (CV) SERIES Brochure
Technical Sheet & Info More Info
Intertek Certificate
Intertek Certificate

Related Models

CR-1000 (SS) SERIES
Stainless Steel Recovery Tank

Certifications

Applicable requirements :
Standard(s) for Electric Vacuum Cleaning Machines and Blower Cleaners (UL-1017)


Features

  • ULPA filter with an efficiency of 99.999% at 0.12 micron. Filtration efficiency of 99.9995% at 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822. All of our ULPA vacuum systems are aerosol leak tested before leaving our facility - included
  • HEPA filter with an efficiency of 99.995% at 0.3 micron. Tested IEST-RP-CC001. H14 by MPPS method as per EN 1822 and OSHA compliant. All of our HEPA vacuum systems are aerosol leak tested before leaving our facility - included
  • Cleanroom compatible with ISO Class 4 (former Class 10). Can be used in the Pharmaceutical industry
  • 5-stage filtration system, includes an ULPA filter (U15), HEPA filter (H14), PTFE laminated main cloth filter, safety filter, and disposable filter bags
  • Designed for the recovery of potent powders in hazardous locations
  • Safe containment canister for the safe collection, containment and disposal of potent compounds included
  • Thru-Flow heavy duty motor
  • Low noise level - only 60 dB(A) at 6.6' (2m)
  • For dry recovery only
  • Autoclavable stainless steel Type 316 filter chamber and wheel base
  • Mounted on a 4-wheel dolly for easy maneuverability
  • 3 optional tool kits - Standard, ESD Safe, and Autoclavable

Technical Specs - North America

Switch to Europe / Asia

Specifications111993A111994A
Model NameCR-1000 (CV)CR-1000 (CV) WITH ULPA PROTECTOR
Type (Powerhead)Electric Electric
Tension120 V120 V
Frequency60 Hz60 Hz
PhaseSingle Single
Wattage1000 W1000 W
Power1.3 HP1.3 HP
Amperage8.3 A8.3 A
Air Flow96 CFM96 CFM
Vacuum Pressure99 " H2099 " H20
Sound Level60 dB(A)60 dB(A)
Type of Power Outlet120V 120V
Suction Inlet Port1.5 " 1.5 "
Cart Type4 Wheel Dolly (4W) 4 Wheel Dolly (4W)
Filter CleaningNone None
Containment Canister Recovery Capacity2 Gal2 Gal
Length23 "23 "
Width16 "16 "
Height26 "26 "
Weight (Vacuum Only)24 lb.24 lb.
Cord Length33 ft.33 ft.
Please note that specifications are subject to change without notice