Ask a Question
EMI-1000 (CV)
Pharma - Dry Recovery Only with Safe Containment Canister for Potent Carcinogenic Powders
/tempFiles/Guest-254.JPG?applID=93&itID=213&scID=147
/tempFiles/Guest-270.JPG?applID=93&itID=213&scID=147 /tempFiles/Guest-267.JPG?applID=93&itID=213&scID=147 /tempFiles/Guest-746.JPG?applID=93&itID=213&scID=147 /tempFiles/Guest-363.JPG?applID=93&itID=213&scID=147 /tempFiles/Guest-852.JPG?applID=93&itID=213&scID=147 /tempFiles/Guest-263.JPG?applID=93&itID=213&scID=147 /tempFiles/Guest-264.JPG?applID=93&itID=213&scID=147 /tempFiles/Guest-265.JPG?applID=93&itID=213&scID=147 /tempFiles/Guest-1927.JPG?applID=93&itID=213&scID=147

Downloads


Description Link
EMI-1000 (CV) Brochure
Technical Sheet & Info More Info
CSA Certificate of Compliance


Certifications

Applicable Requirements :
ANSI/UL 1017
CSA C22.2 No.243


Features

  • ULPA filter with an efficiency of 99.999% at 0.12 micron. Filtration efficiency of 99.9995% at 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822. All of our ULPA vacuum systems are aerosol leak tested before leaving our facility - included
  • HEPA filter with an efficiency of 99.995% at 0.3 micron. Tested IEST-RP-CC001. H14 by MPPS method as per EN 1822 and OSHA compliant. All of our HEPA vacuum systems are aerosol leak tested before leaving our facility - included
  • Cleanroom compatible with ISO Class 4 (former Class 10). Can be used in the Pharmaceutical industry
  • Static free and ESD safe
  • EMI/RFI Shielded
  • TELECOM package available
  • 5-stage filtration system, includes an ULPA filter (U15), HEPA filter (H14), PTFE laminated main cloth filter, safety filter, and disposable filter bags
  • Designed for use in contamination controlled environments
  • Powerful dual speed Thru-Flow motor
  • For dry recovery only
  • Autoclavable stainless steel Type 316 filter chamber and wheel base
  • Safe containment canister for the safe collection, containment and disposal of potent compounds available
  • Mounted on a 4-wheel dolly for easy maneuverability
  • 3 optional tool kits - Standard, ESD Safe, and Autoclavable

Technical Specs - North America

Switch to Europe / Asia

Specifications110132A
Model NameEMI-1000 (CV)
Type (Powerhead)Electric
Tension120 V
Frequency60 Hz
PhaseSingle
Wattage1000 W
Power1.3 HP
Amperage8.5 A
Air Flow120 CFM
Vacuum Pressure95 " H20
Sound Level70 dB(A)
Type of Power Outlet120V
Suction Inlet Port1.5 "
Cart Type4 Wheel Dolly (4W)
Filter CleaningNone
Containment Canister Recovery Capacity2 Gal
Length16 "
Width16 "
Height34 "
Weight (Vacuum Only)36 lb.
Cord Length35 ft.